The requirements for the use of mining sensors are primarily based on the safety monitoring and control needs underground to ensure the safe operation of mine production. Here are some key requirements:
Methane (Gas) Sensor Usage Requirements:
Methane sensors should be installed 10m-15m upwind of any temporarily installed electrical equipment in the return airway, wing return airway, and main return airway of the mining area.
Explosion-proof special-type battery-powered locomotives used in mining must be equipped with an onboard methane cut-off device or a portable methane detection alarm; explosion-proof diesel locomotives used in mining must be equipped with a portable methane detection alarm.

Methane sensors must be installed inside shafts equipped with belt conveyors that also serve as return air shafts.
Methane sensors should be installed above underground coal bunkers, above coal bunkers in surface coal preparation plants, and above enclosed machine rooms in surface coal preparation plants.
Methane sensors should preferably be installed above enclosed surface corridors of belt conveyors.
Methane sensors must be installed indoors within surface gas drainage pump stations, and also in the input pipeline of the drainage pumps. When using gas, a methane sensor should be installed in the output pipeline; when not using gas and using dry gas extraction equipment, a methane sensor should also be installed in the output pipeline.